| Sign In | Join Free | My polstate.com |
|
Model Number : MCPTS3.0
MOQ : 1 pc
Certification : Test Report from CNAS Lab
Delivery Time : 20-25 days
Brand Name : Metrum-Henan
Place of Origin : China
Price : USD5000-10000
Packaging Details : Standard export package
Features
Technical Index
| Accuracy class | 0.05, 0.02 class (optional) |
| Supply Voltage | AC 88-265V, 50/60HZ |
| Input Power Consumption | 450W |
| Ambient Temperature | -10℃-45℃ |
| Influence of auxiliary Voltage | ≤0.005% at 10% Variation |
| Dimension (approx) | 510*600*170mm (main unit) |
| Frequency Range & Resolution | 45-69HZ, 0.001HZ |
| Phase Angle Range & Resolution | 0-359.99°, 0.001° |
| Phase angle Error | 0.03° |
| Communication Interface | RS232 |
Voltage Source
| Voltage Range | 1V-480V (P-N), 120% adjustable |
| Resolution | 0.001 - 0.0001V |
| Output Accuracy | 0.05% |
| Output capacity | 50VA/phase |
| Distortion Factor | ≤0.5% |
| Output Stability | 0.02%/3min |
| Load Regulation (0-100% load) | 0.02% |
Current Source
| Current range | 1mA –20A (Range depends on client, can be maximum 120A), |
| Resolution | 0.0001 - 0.00001A |
| Output Accuracy | 0.05% |
| Output capacity | 100VA/Phase |
| Distortion Facto | ≤0.5% |
| Output Stability | 0.02% / 3min |
| Load Regulation (0-100% load) | 0.02% |
Generation Of Harmonics
| Fundamental Frequency Range | 45-69HZ |
| Harmonics test | 2-63times |
| Phase shift (basic Waveform/Harmonic) | 0-360° |
Configuration & Accessories List
| Item | Quantity |
| Main unit | 1 |
| Voltage cable | 1 set |
| Current cable | 1 set |
| Optical sensor | 1 No |
| Communication cable | 1 |
| Power cord | 1 |
| User manual | 1 |
| PC software (CD) | 1 |
|
|